Heat dissipation
Thermal management for electronic components
Smaller or higher-performance electronic assemblies may require appropriate thermal management to limit overheating and performance loss.
Suitable silicone-based thermally conductive adhesive constructions can transfer heat within an engineered assembly. Cooling performance and long-term suitability depend on the complete thermal design, contact conditions and exposure.
Properties described in the original source:
- Thermal resistance values from 0.37 to 0.64°C-in2/W
- The original source reports 1,000 h at 225°C; verify the exact material and test conditions.
- Thin adhesive construction with wet-out properties appropriate to the specified surface
- Can be cut into suitable customer-specific shapes
- The source describes one- or two-sided adhesive versions, different thicknesses, and polyimide or aluminium carriers. Select the exact construction for the design.
- Die-cut formats for suitable application processes
- The source cites UL 94 V-0 flame classification; verify current test documentation.
- The source cites REACH, RoHS and halogen-free properties; current documentation requires verification.
- ESD-Safe™(DE-F1010, DE-F1012, DE-F1013); verify the actual ESD performance.
| DE-F code | Material | Adhesive | Total thickness | Thermal resistance | Volume resistivity | Temperature |
| DE-F1010 | 12.7 µm polyimide | 40 µm, coated on both sides | 90 µm | 0,53°C-in2/W | 4 x 107 Ω /cm | 1,000 h at 225°C (original test conditions) |
| DE-F1011 | 51 µm aluminium | 40 µm, coated on both sides | 130 µm | 0,37°C-in2/W | < 102 Ω | 1,000 h at 225°C (original test conditions) |
| DE-F1012 | 38 µm Polyimide | 40 µm, coated on both sides | 110 µm | 0,49°C-in2/W | 7 x 106 Ω /cm | 1,000 h at 225°C (original test conditions) |
| DE-F1013 | 38 µm Polyimide | 80 µm, coated on both sides | 190 µm | 0,64°C-in2/W | 4 x 1011 Ω /cm | 1,000 h at 225°C (original test conditions) |
| DE-F1014 | 38 µm Polyimide | 40 µm, coated on one side | 76 µm | 0,44°C-in2/W | 3,4 x 1011 Ω /cm | 1,000 h at 225°C (original test conditions) |
Related information
Personal advice
Which solution fits your application?
We help you select materials and hardware and implement your solution.